SystemTypeKey system data
EuroFine58Hinged, 58 mm, double gasketUf from 1.8 W/m²K; Uw from 1.3 W/m²K (2-sash window 1230 × 1480 mm with 4/16-4 low-e glass); up to 45 dB with the right glass; air permeability class 4; water tightness up to E1800; wind resistance up to C5; security up to RC2
GlassWinHinged with concealed sashUf from 1.30 W/m²K; Uw from 1.7 W/m²K (2 sashes 1230 × 1480 mm, 4/16-4 low-e glass); up to 39 dB; air permeability class 4; water tightness up to E1650; wind resistance up to C5; glass up to 39 mm
PremiLine58Slim sliding systemUf from 2.20 W/m²K; up to 34 dB; air permeability class 4; water tightness 9A
Source: system data sheets at kommerling.mx. Test values for the configurations stated.

Ventanas Ideal Península key facts

ItemValue
Profile brandKömmerling (official distributor)
Main systemsKÖMMERLING76 AD Xtrem (hinged) and PremiLine (sliding); EuroFine58, GlassWin and PremiLine58 to order
Standard glazing6-12-6 double glazing; other configurations to order
Lead time5 to 6 weeks from approval of measurements and receipt of the deposit
WarrantyProfiles 10 years; glass 2 years; manufacturing, installation, hardware and accessories 1 year
Service areaYucatán, Campeche and Quintana Roo
ShowroomCalle 45 n.º 250, Plaza Santander Boreal, Local 18, San Ramón Norte, 97117 Mérida, Yucatán, Mexico
ContactWhatsApp +52 999 434 5072

Glossary of technical terms

Uw

Thermal transmittance of the complete window (profile + glass), in W/m²K. The lower it is, the better it insulates.

Uf

Thermal transmittance of the profile only (frame and sash).

Ug

Thermal transmittance of the glass only.

Solar factor (g or SHGC)

Share of the sun's energy that passes through the glass and turns into heat inside. The lower it is, the less heat. In a hot climate it is the most important glass figure.

Light transmission (LT)

Percentage of visible light the glass lets through.

Rw (dB)

Sound insulation index. The higher it is, the less noise gets in. The values in brackets (C; Ctr) adjust for general noise and traffic noise.

Air permeability (class 1 to 4)

How much air leaks through when the window is closed (EN 1026/12207). Class 4 is the best.

Water tightness (1A to 9A and Exxx)

Resistance to water getting in under rain and wind (EN 1027/12208). Exxx values are the highest.

Wind load resistance (class C1 to C5)

Performance under wind pressure (EN 12210). C5 is the highest class.

RC2 (WK2)

Burglar resistance class under EN 1627.

6-12-6

Double glazing made of two 6 mm panes separated by a 12 mm cavity.

Laminated glass

Two panes bonded by a plastic interlayer (PVB). If it breaks, the pieces stay stuck together. With acoustic PVB it improves noise insulation.

Tempered glass

Heat-treated, stronger glass; if it breaks, it shatters into small pieces.

Solar control / low-e

Invisible coatings on the glass that reduce heat from the sun (solar control) or heat transfer caused by temperature differences (low-e).

Hinged / tilt-and-turn / sliding

Hinged: opens by swinging like a door. Tilt-and-turn: can also tilt in at the top for ventilation. Sliding: the sashes slide along tracks.

Galvanized steel reinforcement

Metal profile inside the PVC that makes frames and sashes stiffer.

FAQ

Which PVC systems do you install?

Mainly KÖMMERLING76 AD Xtrem for hinged windows and doors (casement and tilt-and-turn) and PremiLine for sliding units. We also make EuroFine58, GlassWin and PremiLine58 to order. Everything is made to measure in Mérida.

What glass do the windows have?

As standard, 6-12-6 double glazing: two 6 mm panes with a 12 mm cavity. To order, we make safety or acoustic laminated glass, solar control glass (Saint-Gobain EVO), 10-12-6 and other configurations.

Are PVC windows suitable for the Mérida heat?

Yes. PVC insulates far better than a metal frame. To keep out the sun's heat, the glass is what matters most: solar control glass has a lower solar factor than clear glass.

Does PVC rust in salty coastal air?

No. PVC does not rust or corrode. On the coast you also need to make sure the hardware is suitable for a marine environment.

What maintenance do they need?

Clean them with water and mild soap, and check from time to time that the frame drainage holes are not blocked. They never need painting.

What warranty do you offer?

In writing: 10 years on profiles (composition and color deterioration), 2 years on glass and 1 year on manufacturing, installation, hardware and accessories. It does not cover damage caused by third parties, misuse, impacts, scratches, chemicals or later modifications.

How long does manufacturing and installation take?

5 to 6 weeks from approval of the measurements and receipt of the deposit.

Where do you work?

We have a showroom in Mérida and serve Yucatán, Campeche and Quintana Roo.